pool timer trippers not working

Ideally, the switch would be placed after the timeclock, not before. Any advice? I noticed that they had stopped. The position of the metal bar forces the gear next to it to turn one way or another. Thanks in advanced. I have to reset the time every day. Today is the second day that I have had to turn it on manually. the timer was directly plugged into a gfci and the pump directly into the timer. Hi Agnes, have you tried using a cover pump to remove the rain and/or snow melt from the cover? I reset the breaker and tested the GCFI and I have 240V going in and out of the timer still but my pump isnt moving. It should be 110V or 220V AC. Now Im having to turn my pool pump on and off manually. If the switch simply does not move side to side, it may be a bad clock, if you cannot see what is stopping it from moving. I have a T103 24 hour dial time switch and noticed the time was off so not reading the DO NOT UNSCREW on the pointer I unscrewed it and moved the pointer to the right time and screwed it back tight. Related Reading: Should You Get a Pool Pump Timer? Can I wire this timer to an outlet or should I search for another solution? Posted by 4 years ago. Your timer is on a 24-hour cycle. If they are not moving then you have an issue. Much like your timer pointer, the trippers can become loose and move around as well. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. How to fix a Pool Pump Timer - Easy replacement using the Intermatic T104 Darren Does Everything Pool Timer Not Turning ON or OFF!! 1. 110V or 220V? Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. Resolved! I have a white, red, and black wire coming from the power source. Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. Hi Peter you say that clock is seated correctly, and I assume you mean that the dial is pushed in, or the gear on the back of the dial is engaged with the turning gear. Could be small bugs, or dirt, or both causing the problem. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. I had to order new trippers as mine have been straightened too many times. Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. Do you have an answer to why my pump wont turn off or on? Required fields are marked *. There is a switch control panel and replaced the 20amps DP switch as well. If not, that sounds like a weak/bad motor. To do this, pull the yellow-faced time dial (clockface) toward you. The problem lies, where the power dies, as they say, Thanks for the response. So what you will want to do now is to look for the circuit breaker panel and locate the circuit breaker for your Intermatic Pool Timer and then make sure it is set to the on position. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. Yet another reason why timers dont work properly is the yellow clock wheel is not located or seated properly. You can have as many ON an OFF trippes as you want. It is still moving and it will trip off but not on. My time clock has an ant infestation! Only perform this step if you are qualified. Also I have rotated the dial several times to trip on and off hoping that it lubricates the problem lever and dusts off the coil well. Look into the visual motor check window, near the top of the timer mechanism. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. Check out our online selection of new Intermatic timer clocks at InTheSwim.com! Intermatic pool timers allow you to set specific run-times for your pool filter pump, booster pump, and waterfall pump, so they operate at the most convenient time, or during non-peak energy hours. Thanks for your help! Thanks! Hi Sandra, does the on/off tab switch crisply, or softly? TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. Timer must be reset for current time after power outage. Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. make sure it hasnt tripped and is switched on. The pool was running on a timer. {
If the pump comes on, you definitely have power to the timer. Grab it, pull it towards you, move it around then place it back down. The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. So out comes the soldering gun and the shrink wraps and that did the trick. Common timer problems include the clock not turning, not switching the pump on/off, loose timer pointer and a stopped clock. This site is owned and operated by AJH Trade Group. Two days ago after my pool pump shut off automatically I decided to turn it back on because the pool was still dirty. http://waterheatertimer.org/Tork-timers-and-manuals.html If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. 3. I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. You can also apply some of the troubleshooting steps to other brand timers. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. not sure what is the problem. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. My pool pump and skimmer are on two different motors. Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. Is power reaching the time clock? If your pool pump timer is beyond repair, call a professional to replace it. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . No broken or loose wires visible. View more property details, sales history and Zestimate data on Zillow. Assuming the wiring is all correct. Or is there anything else I can check? Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. The other gears move very slowly, and appear to not move at all, except for one I believe? Back when I was a young technician I was taught to always look for the easy things and use all my senses. Hi Jere, that could be the timer motor failing. For additional tripper pairs on CLOCK-DIALorder 156T1978A. The tripper will not move. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. One morning I noticed my pool didnt automatically turn off. Just above the yellow clock youll see some holes. Gently tighten the screws to securely hold the dogs in place. Any advice on how to fix. Off flipper always works. AJH Trade Group also participate in other affiliate programs. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. Jul 20, 2021. Should it still not work, I suspect a motor failure for the clock. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. Voltage is 243, frequency is 60hz. Does the manual lever stay in the on position always? Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. The on/off pins are tight and pretty new stillany thoughts? You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. You will want to make sure the manual switch under the timer wheel is pushed to the on position. The best pool timers allow you to keep your swimming pool spotless without needing to run your pump around the clock. Hi Davy, It seems flimsy when I click it onOnce on, it works like it should and shuts off every time. Can I spray the timer while there is electricity going in the timer box? If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. Move the switch and see that they separate when off, and come together when on. Hi Bob, you have two blacks and one neutral? Then number(time of day) that you line up with the time marker will be the time that you are setting your timer to. Started about a month ago and I checked the dog tripper at that time and it started working again for awhile but hasn't now for a week. You can turn off Freeze protection and it should stop, or replace the probe if faulty. screwfindinganame on June 18, 2013 at 11:36 pm How can it keep time if lever is in off position (manual lever). Or the switch can suffer wear over many years, and might not make solid contact. i have an oval pool that is closed for the winter but there ha been a problem. I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. "@type": "Organization",
Motor runs past the on dog but doesnt flip pump on? I not sure if this is the best timer to use. I bought a new timer and replace the T104 timer clock. You will first need to adjust the time on the timer first. There could also be other mechanical reasons for this happening, such as a disconnect in the switch. But if the timer doesnt come back on after a storm, there could be an issue. Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. Did you find the issue? Thanks. It stays on until I turn off the circuit breaker. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. What do you suggest to do to get the cover up and the pillows back into position. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. You should be able to see the gears moving. Hi, new timer out of the box, 200V. My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. If not, the motor may be failing. However the new breaker is in a constantly tripped position. Also check that the motor number is compatible with your clock model. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. Hi Mike, yes I sent you an email to your yahoo acct. Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. Black goes to _1 If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. Any ideas why its doing that? We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. My intermatic pool timer will not automatically turn on. With this model can I control both of these motors with two different on and off times. Just replace it and hope for one that isnt defective. But no gears or any sound. Does this mean I need a new T104, or is there a replacement manual on/off switch? Ive got the opposite problem than a lot of people. My original timer worked for 5 years then the clock stopped and I heard no sound. Hello, newer pool guy here. If power is coming to the timer motor, you will clearly see the gears moving through the small window. Now try to jiggle it on and off. Is it keeping time normally? If its not, it wont work properly. If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. As you release the dial, you will feel the gears engage. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. Followed all directions and even watched YouTube troubleshooting videos. March 16, 2022 by WildRiverCountry. That will do it. 120Volt Tork 1101 timers can be fixed with repair parts. I had to replace my 2 year old intermatic timer motor this season as gears werent turning. "address": "",
So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. Basically youre eliminating possibilities until you find the cause. "logo": {
it could also be a failing breaker, but that would be a last resort. Could I send you a picture of my setup? Timer not tripping pump on. The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. First, verify the power is turned off at the breaker panel. It is generally not recommended to reuse a critical fastener like the rear spinal nut on your 2000 Ford Focus. Is this broken? Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. Faulty Pump or Wiring from the Timer to the Pump. Sound right? Jump to the troubleshooting steps below to fix the issue. Inspect the tripper portion, if it looks rounder or worn, replace them. There is power; gears are moving. "wordCount": "1259",
If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. Hi, I got the same problem as my clock not working. Save my name, email, and website in this browser for the next time I comment. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Or fold the cover to one side if needed. But my new timer will not work either. I mean you could go out and buy the timer for the electrician but you will need his experience to get it installed correctly. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. See the next section in this article for that. You need extreme care in this next step. Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. This pool timer is waterproof, heavy-duty, and accurate. I went to the control panel and saw that the timer needle stopped just after the start pointer. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. Morgan Burley Start with the easy checks. I have replaced my pool timer 3 times in the last week and they will work for a day then quit working any idea what the problem could be? It worked for a day but the day after it didnt work. I just replaced an Intermatic WG1573-10D timer motor. You should always be able to switch your pump on and off manually at the timer. After securing the wire conduit (flexible or rigid) to the box, knock out with the proper 3/4 conduit connector. Using Your Timer to Optimize Your Pool Pump Download Article 1 Check the chemical balance of your pool. Either that or if an older clock, the motor may be failing, or the switch mechanism worn (the part that is tripped by the tripper). I had the exact same thing happen recently. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. BUILT BY HAND IN QUEENS, NYC. I have replaced the trippers, but the problem persists. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. You off course will want to adjust one time pin at a time. ft. home is a 3 bed, 4.0 bath property. You can find this in your power board. There are many reasons why your pool timer may not be working. Sometimes its way quick just to replace it rather than spend hours troubleshooting. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. GFCI breakers trip at a very low threshold, doesnt take much. $115 Providence distortion MIJ - $120 All working perfectly Should be clear in photos which include boxes, others will be bubble wrapped and . Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. The works fine and keeps time while it is on but the second it turns the filter off, it stops keeping time and the cogs stop moving. If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. Hi Derrick, first try to reposition the timer tripper, making sure it is all the way on the dial. For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Replaced timer motor on a T10404R Now time is running fast about 2 hrs. It is a good idea to use pliers or a wrench and reseat the trippers, then tighten them at the desired on/off times. On mine, the gears behind the dial look metal, but the motor (behind the plate) they look plastic (maybe?) Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. There are many reasons why your pool timer may not be working. what causes timer on/off pins to bend and how can i prevent timer pins from bending. Watch these tips and tricks before replacing it. These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. Hi Chad, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. My intermatic timer is not turning my pool pump on. Pool timers can also be used to automatically turn on/off pool lights or other outdoor lighting around the pool. The problem lies where the power dies, youve probably heard that before. The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. This will disengage the dial and allow you to spin it in either direction. Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. You will first want to look at the pool timer and see if you have two timer pins. I would suggest calling Intermatic and suggesting that idea and a free replacement? #9. Why it always stop around 10pm by itself and not moving again? i have a P1121 intermatic timer connected to a hayward above ground pool pump. Pull the timer out and turn it to the correct time. You may need to adjust the meshing of the timer motor gear so it runs the clock. Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. Above you said to connect white to A. and Black to 1what do I do with red?